High precision peristaltic pump can produce higher vacuum degree; There are no valves, mechanical seals and other devices, so leakage and liquid overflow; Can easily transport solid, liquid or gas-liquid mixed phase fluid;
High precision peristaltic pump can produce higher vacuum degree; There are no valves, mechanical seals and other devices, so leakage and liquid overflow; Can easily transport solid, liquid or gas-liquid mixed phase fluid; Can transport a variety of grinding, corrosion, oxygen sensitive properties of materials and a variety of food; Only the hose is the part that needs to be replaced, and the replacement operation is very simple; The product is not in contact with any parts except the hose.
High precision peristaltic pump maintenance and maintenance:
1. The filling action of high-precision peristaltic pump is divided into automatic and manual. When the machine is manual, it only needs to push the tongue with the mouth of the bottle, that is, do not stop the tongue when filling. When automatic is adopted, the bottle must be put under the outlet first, and the transfer switch will start filling immediately when it is switched to automatic, and the bottle will be replaced in time.
2. The roller should be oiled regularly to keep the roller in a good lubrication state. Note: the tightness of the roller should be checked when filling oil. If it is found that the roller is too loose, tighten it with the tip pliers. If it is found that the roller is loose and cannot be removed after adjusting the tightness, it should be tested twice for the wear of the inner bearing of the roller, and it can be removed to replace the bearing or the roller.
3. Before the operation of precision peristaltic pump, clean the surface, wipe off the oil or dirt with non-woven soft cloth and cleaning agent, and then dry with non-woven soft cloth. According to the requirements of GMP, check whether the contact parts of equipment and materials meet the corresponding cleaning requirements, if not, clean and dry again. Cleaning method according to technological requirements.
4, when the peristaltic pump is used, the wear of the pump pipe should be checked regularly. Because the peristaltic pump tube is wearing parts, once damaged will cause liquid leakage, so we should timely check the surface of the pump table is the pump has early grinding, in order to prevent the damage of the pump tube.
5. When the metering is found to be unstable during filling, it is necessary to check that the feed check valve may be caught by sundry objects, resulting in lax sealing, affecting the filling amount, and material leakage in the lower part of the cylinder body, indicating that the piston sealing ring is worn and the sealing ring needs to be replaced.