How to use peristaltic pump? When the user uses the product feedback, many users say that the peristaltic pump is easy to use, but at the beginning of use, the operation is not very skilled, and I hope that the manufacturer can produce a pump use method or operating steps. Today, PreFluid has written this article about the use of methods and operating steps for everyone, hoping to help you.
Preparation of peristaltic pump before use
1, open the pump packaging, please check the packing list, check all accessories are wrong or damaged, if found problems, please timely contact the manufacturer or agents
2, carefully read the instruction manual, and keep it at hand, or a fixed place collection, so that you can consult at any time
3, the pump is placed on a horizontal table, the rear distance from the obstacle to keep more than 200 mm distance
Install pump head and pump hose
YZ15 and YZ25 pump heads
1. Push the flat shaft of the pump head into the groove of the drive coupling, turn the pump head so that the positioning hole at the back of the pump head and the positioning pin of the driver pump head support are aligned and pushed into the pump head and the pump head support are fitted, and the two fixing screws are inserted into the fixing holes of the pump head and screwed.
2, pull the pump head lever, open the pump head, put the hose smoothly into the pump head and straighten, pull the lever in the opposite direction to the horizontal position, the hose is installed.
DG pump head
1. Push the flat shaft of the pump head into the groove of the drive coupling, turn the pump head so that the positioning hole at the back of the pump head and the positioning pin of the driver pump head support are aligned and pushed into the pump head and the pump head support are fitted, and the two hex socket fixing screws are inserted into the fixing hole on the inside of the pump head and screwed.
2, put the hose smoothly into the card and straighten, push the tube card at both ends of the hose into the fixed slot, first the left end of the card arc slot in the cylinder guide rail of the pump head, and then the other end of the card into the square guide rail. Power connection The power supply must be the same as that marked on the nameplate at the rear of the chassis. Plug the included power cord into the power socket at the back of the drive. In the shutdown state, press the MODE key to enter the working mode interface, flow mode pump in accordance with the set flow continuously run, and record the accumulated liquid volume
Fluid distribution By setting fluid volume and flow, the pump automatically calculates the distribution time for distribution.
A: The amount of liquid to be dispensed, in optional units (microliter, ml, liter)
B: Flow rate during distribution, unit can be changed (microliter/min, ml/min)
C: Interval. If multiple assignments are made, the time is stopped in between.
D: Allocation times. When the number of distribution is 0 times, the pump will cycle until the start and stop button is pressed. When the number of distribution is 1, the pump only runs 1 time, and the interval is invalid; When the number of distribution is greater than 1, the pump runs to the set number of times and automatically stops.
E: Allocate time. Calculate the estimated time based on fluid volume and time.
3, time allocation by setting the time and flow, the pump automatically calculates the amount of liquid for distribution
A: Time to allocate.
B: Flow rate during distribution, unit can be changed (microliter/min, ml/min)
C: Interval. If multiple assignments are made, the time is stopped in between.
D: Allocation times. When the number of distribution is 0 times, the pump will cycle until the start and stop button is pressed. When the number of distribution is 1, the pump only runs 1 time, and the interval is invalid; When the number of distribution is greater than 1, the pump runs to the set number of times and automatically stops.
E: Dispense fluid. Estimated fluid volume based on time and flow calculations.
Peristaltic pump use precautions:
1, please use the same power supply as the machine nameplate, otherwise it will damage the equipment!
2, do not disassemble the shell and transform the inside of the equipment, otherwise it will cause failure, even electric shock accident!
3, Regarding the maintenance of the product, please contact the dealer or directly with the company.
4. When installing and disassembling the pump tube, please turn off the power supply and do not get close to the rotating roller part to prevent fingers and clothes from being involved in the mechanical mechanism!
5, the pump pipe may be damaged to cause liquid overflow, please take necessary protective measures, regularly check the pump pipe!
6, Install and remove the external control device, be sure to turn off the power to prevent damage to the equipment!
7, then connect the external control or communication interface, please cut off the power!
8, please connect the protective ground of the machine with the ground, otherwise there will be the risk of electric shock or electromagnetic interference!
9, the peristaltic pump pipe is a consumable, after a long time, attention should be paid to the wear of the pipe.
The above content is the "how to use peristaltic pump" all content, if there are any other peristaltic pump needs or questions, you can leave a message, this side will arrange technical call back to answer!