Welcome to PreFluid Technology Co., Ltd.

 |  EN

PreFluid

+86 13861019936 Contact US
Location: Home » News Center » Company News

Contact us

  • No. 8, Fuqiang Road, Xinbei District, Changzhou City, Jiangsu Province
  • pump@prefluid.com
  • +86 13861019936

Peristaltic pump and self-priming pump difference

Release date:Sep 19, 2023 Source:PreFluid Pageviews:-
In the pharmaceutical field. In the laboratory and other fields, peristaltic pumps are often used for liquid dispensing or filling. One advantage of using a peristaltic pump is that it has self-priming capability. Some new users don't know much about these aspects.
In the pharmaceutical field. In the laboratory and other fields, peristaltic pumps are often used for liquid dispensing or filling. One advantage of using a peristaltic pump is that it has self-priming capability. Some new users don't know much about these aspects. Today, what is the self-imbibition of a Pry fluid? What is the difference between it and self-priming pump? Let's explain.
What is the self-priming of peristaltic pump?
When it comes to the self-priming of the peristaltic pump, the distribution peristaltic pump (also known as the filling peristaltic pump according to the purpose) is generally used, mainly for liquid packaging scenes. When separating liquid, after filling the container, switch to the next container and use the self-priming function of the peristaltic pump. If there is no self-priming function, the liquid will drip when switching containers, causing certain pollution and waste, so the self-priming function of the peristaltic pump is also necessary.
How is the self-priming of peristaltic pump produced
Through the working principle of the peristaltic pump, we can know that the peristaltic pump is driven. Pump head and hose composition. During operation, the roller in the pump head squeezes the peristaltic pump tube and alternately squeezes the elastic conveying hose to release the fluid. During the extrusion process, after the roller leaves, the pump tube will return to its natural state. At this time, the pump tube will form a vacuum state, forming the self-priming or back suction function generated at both ends of the pump tube.
Working principle of self-priming pump
The self-priming pump injects water into the pump housing in advance. After starting, through the rotation of the impeller, the liquid in the pump shell is driven to form a vacuum at the pump entrance, and then the liquid is sucked into the work. Self-priming pump is also a centrifugal pump.
Peristaltic pumps are different from self-priming pumps
Through the above, we can know that the peristaltic pump can directly self-priming, and the self-priming pump requires reflux to produce self-priming. However, in terms of quantity, the flow rate of the self-priming pump is much greater than that of the peristaltic pump, so how to choose also depends on the specific use.
Precautions for using peristaltic pumps
1. After the pump tube is used for about 220 hours, the hose can be turned over (that is, 90 degree rotation), because after a long time extrusion of one side of the hose, it is easy to cause unilateral damage, and turning can extend the service life.
2. The storage period of the pump pipe shall not exceed one year (long time without use will lead to aging).
3. Lubricate pump rolls every 6 months (special lubricating oil required).
4. After using the pump for a long time, if there is an abnormal sound, it can be removed to check whether the bearing is worn or damaged. If not, contact the peristaltic pump manufacturer.
5. Since the pump head is used to fix the hose and extrude it to transfer the liquid, the hose should be jammed tightly and not transmitted when loose.
6. Pump pipe may be damaged, resulting in liquid overflow. Please take necessary protective measures and check the pump pipe regularly.
7. When installing and removing the external control device, turn off the power to prevent device damage.
8. Disconnect the power supply when connecting external control or communication ports.
9. Please connect the protected area of the machine to the ground, otherwise there will be the risk of electric shock or electromagnetic interference.
【Tag of this article】:Peristaltic pump and self priming pump difference
【Editor】:PreFluidall rights reserved:https://www.prefluid.netPlease indicate the source

Related News

Industrial peristaltic pump

Industrial peristaltic pump

Industrial peristaltic pump is a very important industrial equipment, usually used to transport a variety of viscous liq...

Apr 08, 2024 Read Details
Peristaltic pump use details

Peristaltic pump use details

Peristaltic pump is a type of pump that realizes fluid transfer by squeezing the hose. Usually, the pressure above 4KG i...

Feb 09, 2023 Read Details
A comprehensive guide to peristaltic pumps to become an expert in industry

A comprehensive guide to peristaltic pumps to become an expert in industry

Peristaltic pump is a kind of equipment that can efficiently and reliably transport fluids, which is widely used in chem...

Feb 07, 2024 Read Details

Contact

  • Telephone: +86 13861019936
  • E-mai: pump@prefluid.com
  • Address:No. 8, Fuqiang Road, Xinbei District,
  • Changzhou City, Jiangsu Province

facebook Twitter linkedin youtube

Leave a Message

Copyright ©Changzhou PreFluid Technology Co., Ltd.. All rights reserved. ICP备案:苏ICP备12035203号-1 Privacy statementTerms & conditions Sitemap