Maintenance measures after peristaltic pump is discontinued

Release date:Sep 05, 2023 Source:PreFluid Pageviews:-
After the purchase of peristaltic pump is used, after a long time, when it is used again, it does not feel as good as before, why is this?
After the purchase of peristaltic pump is used, after a long time, when it is used again, it does not feel as good as before, why is this? Because there is no maintenance measures after deactivation, resulting in aging and other phenomena of some parts, the following Purui fluid for you to introduce the relevant knowledge. What maintenance measures need to be done after deactivation.
Short-term deactivation
1. Check whether the pipeline of the pump is too worn. Turn the pump wheel by hand to see the overall flexibility.
2, if the bearing appears dry wear phenomenon, you can add bearing lubricating oil to the bearing body, observe the oil level should be in the center line of the oil target, the lubricating oil should be replaced or supplemented in time.
3. Check whether the tightening bolt on the pump head of the peristaltic pump is tightened.
Long-term deactivation
1, the peristaltic pump is disabled for a long time, it is necessary to completely disassemble the pump, dry the water, coat the rotating part and the joint with grease, and properly store
2, when the pump is used in winter, it is necessary to unscrew the water plug in the lower part of the pump body to put the medium clean. Prevent frost cracking.
Matters needing attention
1, when buying a pump, when choosing the flow range, do not choose the value that is too far ahead or behind, and should take the middle value.
2, During the re-operation of the pump, the flow and head are controlled within the range indicated on the label to ensure that the peristaltic pump operates at a higher efficiency point in order to obtain good energy saving effects.
3, the pump shaft temperature should not exceed 80 degrees, otherwise it will affect the use of the pump.
4, During the operation, there is a different response to stop the pump inspection, not forced operation.
The above content is about "maintenance measures after peristaltic pump disuse" If you have other questions about peristaltic pump, you can consult the Purui fluid engineer.
【Tag of this article】:Maintenance measures after peristaltic pump is discontinued
【Editor】:PreFluidall rights reserved:https://www.prefluid.netPlease indicate the source

Related News

Choose peristaltic pump should pay attention to the problem

Choose peristaltic pump should pay attention to the problem

As peristaltic pump plays an increasingly important role in the national economy, people pay more attention to peristalt...

Apr 18, 2023 Read Details
Laboratory peristaltic pump silicone hose use precautions

Laboratory peristaltic pump silicone hose use precautions

Laboratory peristaltic pump silicone tube must be tested in all aspects before use, otherwise it will damage the service...

Jan 22, 2024 Read Details
How does peristaltic pump work on the dispensing machine

How does peristaltic pump work on the dispensing machine

Peristaltic dispensing machine is a kind of automatic dispensing equipment, it controls the fluid, the fluid drops on th...

Mar 08, 2023 Read Details

Contact

  • Telephone: +86 13861019936
  • E-mai: pump@prefluid.com
  • Address:No. 8, Fuqiang Road, Xinbei District,
  • Changzhou City, Jiangsu Province

facebook Twitter linkedin youtube

Leave a Message

Copyright ©Changzhou PreFluid Technology Co., Ltd.. All rights reserved. ICP备案:苏ICP备12035203号-1 Privacy statementTerms & conditions Sitemap