There are many articles on the Internet about peristaltic pump explanations, although very detailed, but too long, time-consuming to read. But users want to know as much as possible. Today, Pry Liquid will summarize some knowledge of peristaltic pumps, so that you can understand the products.
1. Peristaltic pump is driven by drive. Pump head and hose is a liquid transport equipment, transport equipment.
2. The transmitted liquid flows only in the hose and does not touch other parts.
3. The transfer of different liquids may require hoses of different materials. If you do not choose, you can consult the Pry liquid sales staff.
4. The transmission accuracy of peristaltic pump is generally 0. About 5%, and the accuracy of some special models will be higher, and the accuracy deviation will be less than 0.2%
5. Simple structure, easy to operate, easy to clean and disinfect. Medicine. Pharmaceutical. Chemical. Food and paper. Printing and other industries.
Peristaltic pump and water pump definition difference
Water pump refers to a broad category including centrifugal pump. Slurry pump, clean water pump and chemical pump, etc. Peristaltic pump can be regarded as one of the pumps, is used to transfer precision fluid equipment, peristaltic pump working principle is also different.
The difference between the two is the use case. If you need to fill a pool or a large cube-shaped storage tank, they are both used as pumps whose main application is efficiency. On the contrary, in some industries such as laboratories. Pharmaceutical. Medical peristaltic pump, etc. Precision transmission, mainly used for precision.
Matters needing attention
1. Peristaltic pump tube may break due to long-term operation damage, resulting in overflow of transmission materials, which may damage the human body or equipment. Please reasonably evaluate the service life of the pump tube, check regularly, and replace the pump tube in time;
2. When disassembling the pump pipe, please disconnect the power supply to ensure that the material in the pipe is discharged clean;
3. Do not touch the pump head roller when the pump is running, so as not to damage the human body or equipment;
4. When the pump is running, the motor temperature rise is high, please touch the motor carefully and perform heat treatment on the motor and circuit;
5. When the pump does not run for a long time, please loosen the pump pipe to prevent its extrusion deformation or even adhesion blockage, which seriously affects the service life;
6. Keep the inner wall of the pump head clean, otherwise it will accelerate the damage of the pump tube and drum;
That's all for "taking you quickly to understand peristaltic pumps". To learn more about peristaltic pumps, check out the rest of the website.