Peristaltic pump can not pump water analysis

Release date:Jul 17, 2023 Source:PreFluid Pageviews:-
In the process of using the peristaltic pump, there may be no water, then what is the reason for this situation? On this issue, peristaltic pump professional manufacturer - Pu Rui fluid take you to understand.
In the process of using the peristaltic pump, there may be no water, then what is the reason for this situation? On this issue, peristaltic pump professional manufacturer - Pu Rui fluid take you to understand.

1. The hose mouth at the suction point inhales the bottom or wall of the container containing the liquid.

Solution: The hose at the suction of the peristaltic pump needs to be reinstalled.

2. Peristaltic pump suction hose has air leakage.

Solution: Replace the leaky pipe.

3. Peristaltic pump suction hose is blocked.

Solution: Remove the blockage or replace the blocked hose.

4. The use of hose with different wall thickness causes the working part of the peristaltic pump to be unable to press the hose tightly, resulting in hose leakage.

Solution: Replace the standard size hose.

5. The pressure gap of the pump head changes, so that it can not be tightly pressed during normal use, resulting in hose leakage.

Solution: If there is no pressure adjustment in the pump head, a new pump head needs to be replaced; If the pump head has a pressure regulation function, you need to adjust the pressure regulation knob until the water enters the hose.
【Tag of this article】:Peristaltic pump can not pump water analysis
【Editor】:PreFluidall rights reserved:https://www.prefluid.netPlease indicate the source

Related News

Peristaltic pump application

Peristaltic pump application

Peristaltic pump is a very common type of pump. Because of its unique working principle and special design, peristaltic ...

Apr 24, 2024 Read Details
Application of peristaltic pump in flue gas analysis of condensate discharge

Application of peristaltic pump in flue gas analysis of condensate discharge

The flue gas usually contains O2, CO, NO, NO2, NOx, s O2, NH3 and other types of flue gas. The gas analyzer is equipped ...

Jan 29, 2023 Read Details
Maintenance measures after peristaltic pump is discontinued

Maintenance measures after peristaltic pump is discontinued

After the purchase of peristaltic pump is used, after a long time, when it is used again, it does not feel as good as be...

Sep 05, 2023 Read Details

Contact

  • Telephone: +86 13861019936
  • E-mai: pump@prefluid.com
  • Address:No. 8, Fuqiang Road, Xinbei District,
  • Changzhou City, Jiangsu Province

facebook Twitter linkedin youtube

Leave a Message

Copyright ©Changzhou PreFluid Technology Co., Ltd.. All rights reserved. ICP备案:苏ICP备12035203号-1 Privacy statementTerms & conditions Sitemap